JG-4020A (Charpy) / JG-4021A (Izod) Digital Dispaly Pendulum Impact Testing Machine
Download Files
JG-4020A_(Charpy)_Catalogue_Digital_Display_Pendulum_Impact_Testing_Machine.pdf (63.99 KB)
JG-4021A_(Izod)_Catalogue_Digital_Display_Pendulum_Impact_Testing_Machine.pdf (60.74 KB)
JG-4020A_(Charpy)_Catalogue_Digital_Display_Pendulum_Impact_Testing_Machine.pdf (63.99 KB)
JG-4021A_(Izod)_Catalogue_Digital_Display_Pendulum_Impact_Testing_Machine.pdf (60.74 KB)
Equipment Usage:
Features:
- JG-4020A Digital Display Pendulum Impact Testing Machine - Charpy, JG-4021A Digital Display Pendulum Impact Testing Machine - Izod.
- Mainly used to make plastics and hard rubber, glass fiber, glass fiber, glass reinforced plastics, electrical insulation materials, floor tile of pottery and porcelain, cast stone, friction material of simply supported beam and cantilever beam impact test.
- GB/T 1043 - 93 'Hard plastic beam impact test method'
- GB/T 1843 - 1996 'Plastic cantilever beam impact test method'
- JB/T 8761 - 1998 'Plastic cantilever beam impact test'
- JB/T 8762 - 1998 'Plastic beam impact testing machine'
- ISO 179 : 1993 'Plastics - Determination Of Charpy Impact Properties'
- ISO 180 : 2000 'Plastics - Determination Of Izod Impact Strength'
- GB/T 18743 - 2002 'Fluid with thermoplastic pipe transmission beam impact test method test method' (that is applicable to pipe impact)
Features:
- Choose imported high precision ball bearing, effective pendulum energy losses to a minimum
- With high precision photoelectric encoder, to avoid the pointer of the friction energy loss, caused by the equipment operation is simple, easy to use
- Using carbon fiber shock, reduce the error brought by itself quality factors
- Can configure multiple pendulum and corresponding support, and easy to change
- Can increase safety nets, improve the security performance of the tester
- Equipped with a special liquid crystal display can display the impact absorbing energy and intuitive accurate without having to read data from the dial, without reading error, high accuracy, high efficiency
- The built-in energy loss can be corrected, making the test results more accurate
- The printer can print out the test report
Model | JG-4020A | JG-4021A | ||
Name | Digital Display Pendulum Impact Testing Machine - Charpy | Digital Display Pendulum Impact Testing Machine - Izod | ||
Pendulum energy | 1J, 2J, 4J, 5J | 7.5J, 15J, 25J, 50J | 1J, 2.75J, 5.5J | 11J, 22J |
Pendulum angle | 150° | |||
Impact speed | 2.9m/s | 3.8m/s | 3.5m/s | |
Distance between center of pendulum and sample | 221mm | 380mm | Distance between pendulum center and impact blade: 335mm | |
Distance between impact blade and jaw | 40mm, 60mm, 70mm, 95mm | Distance between impact blade and jaw: 22mm | ||
Impact blade angle | 30° | |||
Impact blade radius | R=2mm | Blade radius: R=0.8mm | ||
Size (L x H x W) | 700 x 800 x 300 (mm) | |||
Weight | 90Kg | 150Kg | 90Kg | 110Kg |
Power supply | 220V 200W |